Line-Frequency UPS: Mission-Critical Power Protection With 24/7 Burn-In Validated Reliability
Industrial/ line-frequency UPS Introduction
The ZH 1-15KL Series Industrial/ line-frequency UPS ensures robust reliability with full digital microprocessor control for precise power conversion and stability. Its controlled rectifier enhances grid adaptability, while the integrated isolation transformer minimizes neutral-to-ground voltage and harmonic distortion. Dedicated battery terminals prevent installation errors, and 90% industry-certified components ensure durability. Each unit undergoes 24-hour burn-in testing to validate ultra-high reliability, making it ideal for mission-critical applications like data centers and medical facilities. voltage fluctuations, and other power - related issues.
Technical Parameters:
Product Model | 1KVA | 2KVA | 3KVA | 6KVA | 8KVA | 10KVA | 15KVA | |||||
Standard Type | Extended Type | Standard Type | Extended Type | Standard Type | Extended Type | Standard Type | Extended Type | Extended Type | Extended Type | Extended Type | ||
Rated Capacity | 1KVA/800W | 2KVA/1.6KW | 3KVA/2.4KW | 6KVA/4.8KW | 8KVA | 10KVA | 15KVA | |||||
6.4KW | 8KW | 12KW | ||||||||||
Input | Phase | Single - phase | ||||||||||
Voltage | 160 ~ 280Vac | |||||||||||
Frequency | 50Hz±5% | |||||||||||
Output | Voltage | 220Vac±1% | ||||||||||
Frequency | 50Hz±0.1% (Battery operation) | |||||||||||
Waveform | Pure sine wave | |||||||||||
Distortion | < 3% (Under linear full - load condition) | |||||||||||
Efficiency | AC to AC | > 85% | ||||||||||
Transfer Time | 0ms | |||||||||||
DC Start | Adaptable | |||||||||||
ECO Energy - saving Mode | Adaptable | |||||||||||
Redundant Parallel | Adaptable | |||||||||||
Battery | Type | 6 - cell | 6 - cell | 8 - cell | 16 - cell or 8 - cell | 16 - cell | ||||||
Nominal Voltage | 72Vd | 72Vdc | 96Vdc | 192Vdc/96Vdc | 192Vdc | |||||||
Charging Current | 1A (Standard unit), 5A | 5A | ||||||||||
Protection Function | Overload | > 120% overload maintains for 1 min, transfers to bypass or shuts down, > 150% overload maintains for 30 seconds, transfers to bypass or shuts down | ||||||||||
Short - circuit | Circuit automatic protection, bypass switch trips | |||||||||||
Noise Suppression | EMI/RFI filter | |||||||||||
Low Battery | Shutdown protection | |||||||||||
Output Abnormality | Inverter automatic interlock protection | |||||||||||
Peak Factor | 3:01 | |||||||||||
With Generator | Adaptable | |||||||||||
Display Function | LED | UPS operating status | ||||||||||
LCD | Color liquid crystal display: 1. Input status; 2. Output status; 3. Bypass status; 4. Load status; 5. Charging status; 6. ECO mode; 7. Inverter status; 8. Rectifier operation; 9. Inverter temperature; 10. Transformer status; 11. Operating time (days); 12. Device number; 13. Calendar, clock; 14. Model number and specification; 15. Product version number; 16. History accumulation record; 17. History fault record; 18. Language setting; 19. ECO setting; 20. Clock; 21. Daily setup; 22. Battery discharge test, etc. | |||||||||||
Alarm Device | Alarm | Mains failure, rectifier failure, low battery voltage, over - charging voltage, overload, etc. | ||||||||||
Mute | Automatic | |||||||||||
Noise | Distance 1m | <50DB |
Applications:
Servers
Industrial Machinery
Financial Infrastructure
Network Systems
PC Workstations
Security Devices
Educational Facilities
E-Commerce Platforms
Transportation Networks
Laboratory Equipment
Emergency Backup Systems
Medical Devices
Voltage Protection
Blackout Protection
Equipment Protection
Overload Protection
Overcharge Protection
Short-Circuit Protection
Surge Protection
EMI/RFI Noise Suppression