3-phase Industrial Line-frequency UPS: Ultra-Stable Power Safeguard with Isolation Transformer
Product Description:
Our Industrial UPS Power Supply can Achieve 89% efficiency in Commercial Power Mode with our rugged UPS battery backup, engineered for industrial resilience. Featuring robust construction to withstand harsh environments, it ensures seamless operations during outages. Backed by 24/7 remote monitoring, on-site technical support, and proactive maintenance services, we guarantee optimized performance. From professional installation to real-time diagnostics, our end-to-end solutions minimize downtime.
Features:
Blackout Protection
Equipment Protection
Short-Circuit Protection
Surge Protection
EMI/RFI Noise Suppression
Full digital microprocessor control
SCR rectifier + IGBT inverter technology
Technical Parameters:
Product Model | 6KVA Extended Type | 10KVA Extended Type | 15KVA Extended Type | 20KVA Extended Type | 30KVA Extended Type | |
Rated Capacity | 6KVA/4.8KW | 10KVA/8KW | 15KVA/12KW | 20KVA/16KW | 30KVA/24KW | |
Input | Phase | Three - phase | ||||
Voltage | 380Vac + 30% - 22% | |||||
Frequency | 50Hz ± 5% | |||||
Output | Voltage | 220Vac ± 1% | ||||
Frequency | 50Hz ± 0.5% (Battery operation) | |||||
Waveform | Pure sine wave | |||||
Distortion | < 3% (Under linear full - load condition) | |||||
Efficiency | AC to AC | > 85% | ||||
Transfer Time | 0 ms | |||||
DC Start | Adaptable | |||||
ECO Energy - saving Mode | Adaptable | |||||
Redundant Parallel | Adaptable | |||||
Battery | Type | Lead - acid maintenance - free battery | ||||
Number of Cells | 32 | |||||
Nominal Voltage | 384Vdc | |||||
Charging Current | 5A - 10A | |||||
Protection Function | Overload | > 120% overload maintains for 10 min, transfers to bypass or shuts down; > 150% overload maintains for 30 seconds, transfers to bypass or shuts down | ||||
Short - circuit | Circuit automatic protection, bypass switch trips | |||||
Noise Suppression | EMI/RFI filter | |||||
Low Battery | Shutdown protection | |||||
Output Abnormality | Inverter automatic interlock protection | |||||
Peak Factor | 3:01 | |||||
With Generator | Adaptable | |||||
Display Function | LED | UPS operating status, fault status, load status | ||||
LCD | Color liquid crystal display: 1. Input status; 2. Output status; 3. Bypass status; 4. Load status; 5. Charging status; 6. ECO mode; 7. Inverter status; 8. Rectifier operation; 9. Inverter temperature; 10. Transformer status; 11. Operating time (days); 12. Device number; 13. Calendar, clock; 14. Model number and specification; 15. Product version number; 16. History accumulation record; 17. History fault record; 18. Language setting; 19. ECO setting; 20. Clock; 21. Daily setup; 22. Battery discharge test, etc. | |||||
Alarm Device | Alarm | Mains failure, low battery voltage, over - charging voltage, overload, etc. | ||||
Mute | Automatic | |||||
Noise | Distance 1m | <50DB |
Applications:
Home Servers
Industrial Machinery
Financial Infrastructure
Network Systems
PC Workstations
Security Devices
Educational Facilities
From data centers to medical facilities, the 3-phase line frequency UPS robust design and fail-safe protections ensure continuous power integrity, even in mission-critical environments.